We are pleased to inform all our partners that the new generation PiloTREK W-100 level transmitters are available, the production and the shipments are continuous since November 2012.
Adjustment, programming: Large Dot Matrix graphic display with backlight.
Text-based menu system / 6 button programming
Functions: Power supply for 2-wire HART transmitters
Displaying the measured values numerical and in bargraph form.
Programming of NIVELCO made transmitters.
Process control tasks (multiple analogue or relay outputs)
Control outputs: Current generators, Relays, RS485 communication line (with HART or MODBUS protocol)
APPLICATION CONSIDERATIONS :
Mounting, installation: To wall or DIN rail
TECHNICAL DATA :
Power supply: 11,4…40 V DC, 11,4…28 V AC, 85…255 V AC
Ambient temperature: -30…+50°C
Inputs: Max.15 HART capable transmitter (Max. 4 for Ex transmitters)
Outputs: Max 2 galvanically separated 4…20 mA current output, Max 4 relays (SPDT), 1pc RS485 interface
Expansion modules: Max 32pcs PJK-100 universal interface modules
Max number of total internal and external outputs is 64pcs.
Protection: IP65
Ex marking: ATEX II (1) G [EEx ia] IIB
FEATURES
Programmer, indicator and controller for transmitters with HART protocol
Highly informative Dot-Matrix display back light
Tank visualisation
Data Logger
Menu-based simple 6-key programming
1 to 15 input channels
Transmitter diagnostic capabilities
Explosion-proof models
APPLICATIONS
Programmer, indicator and controller for single transmitters and for transmitter groups
RS485 comm. line with HART or MODBUS protocol
SPECIFICATIONS
Power supply: 11.4-40 V DC, 11.4-28 V AC or 85-255 V AC
Ambient temperature: -30…+50 °C
Input from transmitters: HART
Outputs, (depending on order):
max. 2: 4-20 mA
max. 4: SPDT relays
RS 485
Outputs, extended with PJK-100 universal interface modules:
max. 16: 4-20 mA
max. 64: SPDT relays
Communication with host: RS 485
Protection: IP65
Approval: ATEX II (1) G [Ex ia Ga] IIB
FEATURES ::
Programmer, indicator and controller for transmitters with HART protocol
Highly informative Dot-Matrix display back light
Tank visualisation
Data Logger
Menu-based simple 6-key programming
1 to 15 input channels
Transmitter diagnostic capabilities
Explosion-proof models
APPLICATIONS ::
Programmer, indicator and controller for single transmitters and for transmitter groups
RS485 comm. line with HART or MODBUS protocol
SPECIFICATIONS ::
Power supply: 11.4-40 V DC, 11.4-28 V AC or 85-255 V AC
Ambient temperature: -30…+50 °C
Input from transmitters: HART
Outputs, (depending on order):
max. 2: 4-20 mA
max. 4: SPDT relays
RS 485
Outputs, extended with PJK-100 universal interface modules:
max. 16: 4-20 mA
max. 64: SPDT relays
2013 - Fenes Valley hydroelectric power station, Romania :: Distributor: NIVELCO Tehnica Masurarii
Flow metering solution for small hydroelectric power stations. The water which drives the turbines is measured by insertion type electromagnetic flowmeters. In order to provide be minimum required water amount in the stream an open channel flowmeter system with EasyTREK ultrasonic level transmitter, NIVOSONAR GPA Parshall flume and MultiCONT process controller is used. This system controls a dam gate (open-close) to provide the specified minimum yield. This water volume should provide proper living space for the water creatures in the river downstream under the dam.
NIVELCO's THERMOPOINT multipoint temperature transmitters are ideal solutions in order to meet all quality requirement parameters of long term grain storage. In Piskolt, Romania 17 THERMOPOINT temperature transmitters with 5 or 7 sensors are used in the 300, 500 and 1000 tonne silos. The measured temperature values are processed and displayed with two MultiCONT multichannel process controller units.
Nivelco's instruments:
THERMOPOINT-TMH-559-8 Ex - 5 pcs
THERMOPOINT-TMH-57D-8 Ex - 12 pcs
MultiCONT-PRW-2MA-1 - 2 pcs
224,600
2013 - Zsóry Spa, Mezőkövesd, Hungary
The thermal wells of the Zsóry Spa are obligated to be continuously monitored and registration is also required for the measured level and temperature values. One of the 140m deep wells is equipped with NIVOPRESS NPP-58A-6Ex borehole hydrostatic level transmitters with integrated Pt100 temperature sensor. The water is 47°C hot and hydrogen sulphuric so the cable is FEP coated. The measurement values are transferred to a MultiCONT PRD-22A-5Ex and stored in an SD card which is read out regularly.
Nivelco's instruments:
NIVOPRESS NPP-58A-6 Ex
MultiCONT PRD-22A-5 Ex
UNICONT PTF-401-4
NIPOWER PPK-331-1
224,525
2012 - PETROL Kft, Budapest, Hungary
In the Hungarian capital city, the Budapest Water Works Company has numberless trucks and cars. The great amount of fuel consumption is supplied from their own petrol station. These small stations use NIVOTRACK magnetostrictive level transmitters to monitor the fuel level and the measured data are processed by MultiCONT process controllers.
Nivelco's instruments:
NIVOTRACK MTA-514-7 - 1 pc
NIVOTRACK MTA-516-7 - 1 pc
NIVOTRACK MTA-518-7 - 1 pc
NIVOTRACK MTA-520-7 - 1 pc
NIVOTRACK MTA-522-7 - 1 pc
MultiCONT PEW-21A-5 - 2 pcs
MultiCONT PEW-24A-5 - 2 pcs
220,005
2012 - Urban waste water treatment plant, Portugal :: Distributor: BRESIMAR Automacao S.A.
The urban waste water treatment plant in Portugal use EasyTREK ultrasonic level transmitters for open channel flow measurement and level measurement in the concrete open tanks. The water quality is monitored by AnaCONT ORP (oxidation / reduction potential) and DO (dissolved oxygen) transmitters. The transmitters are connected to MultiCONT process controllers .
EasyTREK integrated ultrasonic level transmitters measure the level in 13 storage silos of various dusty aggregates. The transmitters are connected to MultiCONT multichannel process controllers which communicates by MODBUS RTU protocol with the PLC.
2012 - United Arab Emirates, Dubai :: Distributor: Dutco Tennant LLC.
Oil tank park in Dubai is equipped with MicroTREK guided radar level transmitters and THERMOPOINT multipoint temperature transmitters. The system is monitored by NIVISION process visualization software.
The fish farming plant uses AnaCONT LED dissolved oxygen transmitter in the aerating system which is controlled this way in accordance to the measured DO values.
In this application, we measure the Overflow with EasyTREK SPA ultrasonic integrated transmitter connected to a MultiCONT PEW multichannel controller, powered by a battery and reloaded by a solar panel. A 20-point linearization table are programmed in the MultiCONT to convert level to flow with Manning Strickler Formula (relation between level and flow in a circular pipe). 4-20 mA output and pulse relay are wired to a small GSM transmitter. All units are powered by the solar panel.
NIVELCO instruments are used in the pesticide production of Agrokémia Sellye Zrt. All transmitters and infra-red sensors are connected to the controlling server. This computer is running a NIVISION process visualization software which enables the unified data management of the measurement values, visual displaying of each process and batch tracking with receipt logging.
2012 - ERHAL Kft., Romania :: Distributor: NIVELCO T.M. S.R.L.
Open channel ultrasonic flow measurement in a trout farming plant in Transylvania. The applied Parshall flume is equipped with a EasyTREK integrated transmitter.
The NT Food Kft. in Kiskunfélegyháza
produces hot pressed, extracted, raw
and refined sunflower cooking oil, their best-known brand in Hungary is
called Kunsági Éden. The company is
the largest Hungarian owned edible
oil producer for over 15 years. The implemented measurement system monitors the batch numbers assigned to the raw materials during
the whole manufacturing process from the input seed state to the bottled oil state.
The stock management of Nigeria’s largest oil retailer (OANDO) has been monitored on-line thanks to a Hungarian development, a complex remote object-monitoring system. This solution was born from the close cooperation of two Hungarian company groups – Lambda-Com Kft. and NIVELCO Process Control Co. – which is able to provide continuous
and accurate level monitoring. In addition to this the system facilitates the more efficient stock management and the organization of the fuel-delivery.
2011 - Wastewater treatment plant, France :: Distributor: C2Plus
NIVELCO liquid analytical instruments are operating in a French wastewater treatment plant. A measurement system with AnaCONT redox-potential & dissolved oxygen transmitters and MultiCONT process controller optimize the aeration process.
2011 - Sewage works of Vienna, Austria :: Distributor: Göth Solutions
Sewage works of Vienna use NIVELCO instruments in the drain-system under Karlsplatz. The water level is monitored with EasyTREK integrated ultrasonic transmitters and MultiCONT process controllers.
2011 - VA-TECH WABAG - Chennai, India :: Distributor: NIVELCO India Pvt. Ltd.
Level measurement in open reservoirs with NIVOPRESS N hydrostatic borehole level transmitters. The transmitters in the sewage station of Aden, Yemen are displayed with MultiCONT controller.
2011 - Allison Transmission Site in Szentgotthárd, Hungary
NIVELCO delivered its MicroTREK HT-400 guided radar transmitters for oil and oil-emulsion tanks in the new site of Allison Transmission in Szentgotthárd.
Accurate and linearized level measurement of different fuels in service stations using guided microwave radars. The system is completed with MultiCONT controllers and Nivision software. The advantage of Nivision supervision is the WEB access.
1. picture : before : STA-244 2. picture : now : SPA-340-4 3. picture : Parshall
: SPA-360-4
Level measurement in sewage basin now and before.
Outgoing sewage measurement with Parshall flume
Nivelco's instruments:
SPA340-4
PMG 411
PPK-331
SPA-360-4
PEC-110-1
146,880
2008 - Gran Milano SpA, Milano, Italy :: Distributor: Isoil Industria SpA
Continuous level measuring of sugar and flour in tanks with 6 and 12m heigth with MicroTREK TDR level transmitters. Signal processing is done by MultiCONT PRW process controller.
Nivelco's instruments:
MicroTREK
MultiCONT
UNICONT PJK
141,110
2008 - Dunamenti Regionális Vízmű., Vác, Hungary
Level measuring and control of the central sewage pump of the sewage network of Veresegyház. Signal processing and control is done by MultiCONT process controller.
Nivelco's instruments:
SPA-340-4
PEW-114-1
140,490
2008 - Dunamenti Regionális Vízmű., Szentendre, Hungary
Level measuring and control of several sewage shafts of the municipal sewage network. Signal processing and control is done by MultiCONT process controller.
Nivelco's instruments:
SPA-340-4
PEW-114-1
140,482
2008 - Saint Gobain Weber Terranova Kft., Pilisvörösvár, Hungary
Continuous level metering of outdoor dolomite silos and solvent tanks with MicroTREK TDR radars and ultrasonic transmitters. Signal processing is done by MultiCONT and Unicont controllers.
Nivelco's instruments:
HTN-204-4 : 10 pcs.
PRW-1MA : 1 pc.
SEP-380-4 : 5 pcs.
PMM-314-1 : 5 pcs.
140,325
2008 - Kemenesvíz Kft., Celldömölk, Hungary
Measuring of the drawn water of the local sewage plant with ultrasonic transmitter and Parshall flume. The processing and evaluation is done by a Multicont process controller.
Various level metering tasks in cooking oil vessels of a turkey meat processing plant. Nivelco's NIVISION ensures plant control transparency.
Nivelco's instruments:
2 pcs. of NivoTRACK MTA-326-4
1 pc. of MultiCONT PRW-14A-1
NIVISION proccess visualization software
112,809
2006 - Agribrands Europe Hungary Kft., Kaposvár, Hungary
Level metering of various feed stuff in 4 pcs. of 12m tall and 4pcs. of 22m tall silos. Measured values can be queried either with a MULTICONT or with a PC based system via RS485 interface.
80 Silos of Japanese animal food plant equipped with NIVELCO'S EchoTREK's.
Smart solution of a challenging level measurement task for grains, ground grain derivatives, chemicals and animal food pellets in extremely slim silos with ultrasonic transmitters involving HART multidrop system.